The YN3030A three-phase AC and DC standard source adopts a meter-source integrated structure, all-digital closed-loop standard source technology, using embedded systems, large-screen TFT color liquid crystal displays and touch screens, CPLD chips, and a series of devices such as high-precision A/D, D/A, etc. , Small size and light weight, can be widely used in the electric energy measurement industry, electrical laboratories and other related departments, and it is easy to carry to the scene.
1. The touch screen control panel and mask buttons are used to display a large amount of information and easy to use.
2. Built-in high-level standard electric energy meter, and use it as a standard for digital closed-loop feedback, voltage, current, frequency, phase, active power, reactive power, apparent power, power factor and other parameters can be used as standards.
3. With multiple protection functions: current limiting protection, power amplifier protection, voltage short circuit protection, current open circuit protection, power amplifier thermal protection and other functions.
4. Intelligent gear position: within the allowable output range of the instrument, the user can arbitrarily set the respective rated voltage and current gear positions of the three-phase voltage and current. The test points and adjustment fineness of voltage and current refer to the rated gear position set by the user Value, convenient for user operation. ▫ ▫ ▫ ▫ ▫ ▫
5. Abundant test points for current and power factor, easy to configure various calibration schemes.
6. The data storage capacity is large, and the verification data can be easily inquired.
7. With RS232 serial port, it is convenient for computer control and software upgrade.
1.1 Power output:
1.1.1 AC voltage output
Adjustment fineness: 0.01%RG
Resolution: 6 significant digits
Accuracy: better than ±0.05%RG
Stability: better than ±0.01%RG/1min
Distortion: better than 0.3% (non-capacitive load)
Output power: rated 20VA per phase
Full load adjustment rate: less than ±0.01%RG
Output range: 10V~460V
Gear setting: 57.7V, 100 V, 220V, 380V, internal automatic gear switching.
1.1.2 AC current output
Adjustment fineness: 0.01%RG
Accuracy: better than ±0.05%RG
Resolution: 6 significant digits
Stability: better than ±0.01% RG /1min
Distortion: better than 0.3%
Output power: rated output 20VA per phase gear.
Full load adjustment rate: less than ±0.01%RG
Output range: 1mA~24A
Gear setting: 0.2A, 1A, 5A, 20A, automatic gear switching
1.1.3 Power output
Accuracy: Better than 0.05%RG
Stability: Better than 0.01%/1min. To
Resolution: 6 significant figures (active power, reactive power, apparent power)
1.1.4 Power factor
Adjustment range: -1~0~+1;
Resolution: 0.00001;
Accuracy: 0.0005.
1.1.5 Phase
Adjustment range: 0~359.99°
Resolution: 0.001 °
Accuracy: ±0.02°
1.1.6 Frequency
Adjustment range: 40Hz~70Hz
Resolution: 0.001Hz
Accuracy: ±0.002Hz
1.1.7 Harmonics
The YN3030A three-phase AC/DC standard source can accurately output the 2~51th harmonics. The harmonics can be combined and output at the same time at the same time, but the total harmonic content rate when outputting the harmonics should not exceed the limit listed in the table below. . Harmonic content display accuracy is 0.1%, and harmonic content display resolution is 4 significant digits. The adjustment range of harmonic phase (relative to the fundamental wave) is 0-359.99°.
Harmonic order Voltage harmonic content rate (relative to fundamental wave)
2-8 40%
9-15 30%
16-31 20%
32-51 5%
1.2 Technical indicators for calibration of electric meters
Device output power pulse constant: 18000000×5/In
(Note: In is the current gear value in the standard source 60 (100), 20, 5, 1, 0.2)
Output pulse level: 5V
Number of input pulse channels of watt-hour meter: 1 channel
Watt-hour meter input pulse level: within 5V or passive
Error display range of watt-hour meter: ±0.000%--±99.99%
Error display resolution of watt-hour meter: 0.001%
Watt-hour meter constant input range: 6 significant digits, decimals are allowed.
The test points for meter calibration include: Imax, 0.5 Imax, 1.2Ib, 1Ib, 0.5 Ib, 0.2 Ib, 0.1 Ib, 0.05 Ib, 0.02 Ib, 0.01 Ib.
The power factor test points that can be set for meter calibration are 1.0, 0.5L, 0.8C, and 0.5C.
The setting range of the calibration circle of the electric meter is 1-9999.
1.3 Commonly used output adjustment test points provided when the instrument is used as a standard source
Voltage test points: 10%, 20%, 50%, 80%, 100%, 110%, 120%.
Current test points: 5%, 10%, 20%, 30%, 50%, 70%, 100%, 120%.
Phase test points: 0.5L, 0.8L, 1.0, 0.8C, 0.5C.
The amplitude of the three-phase voltage and current can be adjusted separately, the adjustment fineness: 10%, 1%, 0.1%, 0.01%; the adjustment range is 125%.
The phase and power factor of the three-phase voltage and current can also be adjusted in phases, with adjustment finenesses of 10°, 1°, 0.1°, and 0.01° respectively.
The phases of UB and UC can also be adjusted separately for UA.
The frequency adjustment is adjusted by the three-phase voltage and current together, and the adjustment fineness is 5Hz,
1 Hz, 0.1 Hz, 0.01 Hz.
1.4 Power supply
Single-phase AC 220V, 50/60Hz.
1.5 External dimensions
480*600*178mm
1.6 weight
Weight 27Kg.
- Display screen
Keypad
Output
Our company's products are produced in strict accordance with international standards, national standards, and industry and enterprise standards. They have passed professional inspections by national, provincial and municipal electric power research institutes, measurement centers and electric power authorities, and fully passed the ISO9001 international quality management system certification. GB/T19001-2008 quality management system requirements, GB/T24001-2004 environmental management system requirements, GB/T28001-2011 occupational health and safety management system requirements.
-
Pre-sale commitmentWarmly welcome calls and visits
Provide fast and professional response
Timely, serious and reasonable quotation -
Commitment in saleStrictly execute the contract
Professional technical training
Timely and regular return visits -
After-sales servicePunctual delivery with quality and quantity
Take information feedback seriously
Free lifetime technical consultation