Manual
Certificate
Video
- 027-81314188
- 2364840384
The "Administrative Measures for Installation (Repair, Test) Power Facilities Permits" will come into effect on October 11, 2020. The "Administrative Measures for Installation (Repair, Test) Power Facilities License" (State Electricity Regulatory Commission Order No. 28) promulgated by the former State Electricity Regulatory Commission on December 18, 2009 shall be repealed simultaneously. Huatian Power briefly introduces the new version of the guide for the selection of construction machinery and equipment required for the second-level power facility license for installation (repair, test) testing.
Obtain the second-level installation (repair, test) license, and can engage in the installation, maintenance or test activities of power facilities with voltage levels below 330kV.
承试类 二级
序号 | 机具设备名称 | 单位 | 数量 | 规格 | 规格型号 |
一 | 高压发生设备 | ||||
1 | 直流高压发生器 | 套 | 1 | DC:250kV/5mA | YNZGF-250kV/5mA |
2 | 工频耐压试验装置 | 套 | 1 | AC:10kVA/100kV | YNYDJ-10kVA/100kV |
套 | 1 | AC:5kVA/50kV | YNYDJ-5kVA/50kV | ||
3 | 变频串联谐振试验成套装置 | 套 | 1 | 2000kVA/400kV/5A 30~300Hz |
YNXZ-2000kVA/400kV |
4 | 感应耐压试验装置 | 套 | 1 | 5kVA/360V 150Hz |
YNSBF-5kVA/360V |
二 | 电气测量仪器 | ||||
1 | 高压介质损耗测试仪 | 台 | 2 | 1、介质测量精度为1% 2、电容量精度为0.5% 3、抗干扰变频 |
YNJS-H |
2 | 回路电阻测试仪 | 台 | 2 | DC:≥100A | YNHL-100A |
3 | 互感器伏安特性测试仪 | 台 | 1 | 2200V/5A | YNFA-V |
4 | 接地电阻测试仪 | 台 | 1 | 异频法 | YNDW-3A |
5 | 电容电感测试仪 | 台 | 1 | YNRG-H | |
6 | 接地导通测试仪 | 台 | 1 | DC:1A | YNDT-10A |
7 | 变压器直流电阻测试仪 | 台 | 2 | DC:≥10A | YNZZ-10A |
8 | 变压器变比测试仪 | 台 | 1 | 数字式0.5级 | YNBC-H |
9 | 变压器绕组变形测试仪 | 台 | 1 | 频响法 | YNRZ-800A |
10 | 有载分接开关测试仪 | 台 | 1 | I≧1A | YNYZ-H |
11 | 断路器特性测试仪 | 台 | 2 | YNGKC-6F | |
12 | 氧化锌避雷器阻性电流测试仪 | 台 | 1 | YNYB-H | |
13 | 三相继电保护测试仪 | 台 | 2 | 三相电压电流各2组 | YNJB-1200 |
14 | 输电线路参数测试仪 | 台 | 1 | 异频法 | YNXL-Y |
15 | 雷击计数器校验仪 | 只 | 1 | YNFD-H | |
16 | 绝缘电阻测试仪 | 台 | 2 | DC:0~5000V 200G(Ω) 短路电流≥5mA |
YN-5000 |
三 | 油、气试验仪器 | ||||
1 | SF6检漏仪 | 台 | 1 | 灵敏度1ppmv | YNXP-1A |
2 | SF6气体微水测试仪 | 台 | 1 | YNWS-H | |
3 | SF6气体密度校验仪 | 台 | 1 | 精度0.2级 压力范围0~1.0Mpa |
YNMD-H |
4 | 绝缘油色谱仪 | 台 | 1 | YNYSP-2030 | |
5 | 绝缘油闭口闪点仪 | 台 | 1 | YNBS-H | |
6 | 绝缘油微水仪 | 台 | 1 | PPM级 | YNYWS-H |
7 | 绝缘油酸值测定仪 | 台 | 1 | YNYSZ-H | |
8 | 绝缘油PH测定仪 | 台 | 1 | ||
9 | 绝缘油自动介质损耗测量仪 | 台 | 1 | YNYJS-H | |
10 | 绝缘油介电强度测试仪 | 台 | 1 | YNJY-1001 | |
四 | 常用仪器仪表 | ||||
1 | 兆欧表 | 只 | 2 | DC:2500V | YN2671 |
2 | 兆欧表 | 只 | 2 | DC:500V | YN2670 |
3 | 数字式双钳相位伏安表 | 只 | 2 | 测量电流1mA~5A | SMG2000B |
Those who have obtained the second-level test-based installation (repair, test) power facility license can engage in testing activities for power facilities with voltage levels below 330kV. Applicants should meet the following conditions:
1. Net assets
Have net assets that are suitable for carrying out installation (repair, test) power facilities activities, and their proportion of total assets shall not be less than 15%.
2. Person in charge of technology and person in charge of safety
Those who apply for Level 1 to Level 3 licenses shall have at least 5 years of work experience in installation, maintenance or test management of electric power facilities that are compatible with the type of license applied for, and have a professional title of power-related major or above; among them, those who apply for a Level 1 license , Should have professional titles related to electric power.
3. Professional technical and skilled personnel
For those who apply for a Level 1 to Level 3 license, there shall be no less than 50, 30, and 15 electric power-related professional and technical personnel, among which there are no less than 30, 15 and 5 persons with intermediate or higher technical qualifications; There are no less than 60, 30, and 20 relevant professional skilled personnel, among which there are no less than 30, 15 and 10 high-voltage electricians.
4. In addition to the above requirements, applicants who apply for a Level 1 to Level 3 license shall also have the following performances that are compatible with the type and level of the license applied for:
1. Those who apply for Class 1 to Class 3 installation permits shall be engaged in the installation of power transformation (distribution) and line facilities with voltage levels of 330 (220) kV, 110 (66) kV, 35kV and above 10kV and above in the past 3 years. The performance of the activities and the quality are qualified; during this period, the annual project settlement income from the installation of power facilities shall be no less than 200 million yuan, 100 million yuan and 30 million yuan respectively.
2. Applicants who apply for Grade I to Grade III repair or test licenses shall be engaged in 330 (220) kV, 110 (66) kV, 35kV and 10kV and above voltage level transformation (distribution) electricity in the past two years. And the performance of maintenance or test activities of line facilities.
Our company's products are produced in strict accordance with international standards, national standards, and industry and enterprise standards. They have passed professional inspections by national, provincial and municipal electric power research institutes, measurement centers and electric power authorities, and fully passed the ISO9001 international quality management system certification. GB/T19001-2008 quality management system requirements, GB/T24001-2004 environmental management system requirements, GB/T28001-2011 occupational health and safety management system requirements.
-
Pre-sale commitmentWarmly welcome calls and visits
Provide fast and professional response
Timely, serious and reasonable quotation -
Commitment in saleStrictly execute the contract
Professional technical training
Timely and regular return visits -
After-sales servicePunctual delivery with quality and quantity
Take information feedback seriously
Free lifetime technical consultation