The "Administrative Measures for Installation (Repair, Test) Power Facilities Permits" will come into effect on October 11, 2020. The "Administrative Measures for Installation (Repair, Test) Power Facilities License" (State Electricity Regulatory Commission Order No. 28) promulgated by the former State Electricity Regulatory Commission on December 18, 2009 shall be repealed simultaneously. Huatian Power briefly introduces the new version of the guide for the selection of construction machinery and equipment required for the third-level power facility license for installation (repair, test) testing.
Obtain a three-level installation (repair, test) license, and be able to engage in installation, maintenance or test activities of power facilities with voltage levels below 110 kV.
Tested Class III
Serial number | Machine equipment name | Unit | Quantity | Specification | Specification model |
One | High-voltage generating equipment | ||||
1 | DC high voltage generator | set | 1 | DC:200kV/3mA | YNZGF-200kV/3mA |
set | 1 | DC:120kV/2mA | YNZGF-120kV/2mA | ||
2 | Power frequency withstand voltage test device | set | 1 | AC:10kVA/100kV | YNYDJ-10kVA/100kV |
set | 1 | AC:5kVA/50kV | YNYDJ-5kVA/50kV | ||
3 | Induction withstand voltage test device | set | 1 | 500kVA/200kV/2.5A 30~300Hz |
YNXZ-500kVA/200kV |
4 | Induction withstand voltage test device | set | 1 | 5kVA/360V 150Hz |
YNSBF-5kVA/360V |
Two | Electrical measuring instruments | ||||
1 | High voltage dielectric loss tester | station | 2 | 1. The medium measurement accuracy is 1% 2. The capacitance accuracy is 0.5% 3. Anti-interference frequency conversion |
YNJS-H |
2 | Loop resistance tester | station | 2 | DC:≥100A | YNHL-100A |
3 | Transformer volt-ampere characteristic tester | station | 1 | 1100V/5A | YNFA-II |
4 | Ground Resistance Tester | station | 1 | Inter-frequency method | YNDW-3A |
5 | Capacitance and inductance tester | station | 1 | YNRG-H | |
6 | Ground continuity tester | station | 1 | DC:1A | YNDT-10A |
7 | Transformer DC Resistance Tester | station | 2 | DC:≥10A | YNZZ-10A |
8 | Transformer ratio tester | station | 1 | Digital 0.5 level | YNBC-H |
9 | Transformer winding deformation tester | station | 1 | Frequency response method | YNRZ-800A |
10 | On-load tap changer tester | station | 1 | I≧1A | YNYZ-H |
11 | Circuit breaker characteristic tester | station | 2 | YNGKC-6F | |
12 | Zinc oxide arrester resistive current tester | station | 1 | YNYB-H | |
13 | Three-phase relay protection tester | station | 2 | Two groups of three-phase voltage and current | YNJB-1200 |
14 | Lightning strike counter calibrator | only | 1 | YNFD-H | |
15 | Insulation Resistance Tester | station | 2 | DC:0~5000V 200G(Ω) Short circuit current ≥3mA |
YN-5000 |
Three | Oil and gas test equipment | ||||
1 | SF6 leak detector | station | 1 | Sensitivity 1ppmv | YNXP-1A |
2 | SF6 Gas Moisture Tester | station | 1 | YNWS-H | |
Four | Commonly used instruments | ||||
1 | Megohmmeter | only | 1 | DC:2500V | YN2671 |
2 | Megohmmeter | only | 1 | DC:500V | YN2670 |
3 | Digital double clamp phase voltammeter | only | 1 | Measuring current 1mA~5A | SMG2000B |
Those who have obtained a three-level test-based installation (repair, test) power facility license can engage in testing activities for power facilities with voltage levels below 110kV. Applicants should meet the following conditions:
1. Net assets
Have net assets that are suitable for carrying out installation (repair, test) power facilities activities, and their proportion of total assets shall not be less than 15%.
2. Person in charge of technology and person in charge of safety
Those who apply for Level 1 to Level 3 licenses shall have at least 5 years of work experience in installation, maintenance or test management of electric power facilities that are compatible with the type of license applied for, and have a professional title of power-related major or above; among them, those who apply for a Level 1 license , Should have professional titles related to electric power.
3. Professional technical and skilled personnel
For those who apply for a Level 1 to Level 3 license, there shall be no less than 50, 30, and 15 electric power-related professional and technical personnel, among which there are no less than 30, 15 and 5 persons with intermediate or higher technical qualifications; There are no less than 60, 30, and 20 relevant professional skilled personnel, among which there are no less than 30, 15 and 10 high-voltage electricians.
4. In addition to the above requirements, applicants who apply for a Level 1 to Level 3 license shall also have the following performances that are compatible with the type and level of the license applied for:
1. Those who apply for Class 1 to Class 3 installation permits shall be engaged in the installation of power transformation (distribution) and line facilities with voltage levels of 330 (220) kV, 110 (66) kV, 35kV and above 10kV and above in the past 3 years. The performance of the activities and the quality are qualified; during this period, the annual project settlement income from the installation of power facilities shall be no less than 200 million yuan, 100 million yuan and 30 million yuan respectively.
2. Applicants who apply for Grade I to Grade III repair or test licenses shall be engaged in 330 (220) kV, 110 (66) kV, 35kV and 10kV and above voltage level transformation (distribution) electricity in the past two years. And the performance of maintenance or test activities of line facilities.
Our company's products are produced in strict accordance with international standards, national standards, and industry and enterprise standards. They have passed professional inspections by national, provincial and municipal electric power research institutes, measurement centers and electric power authorities, and fully passed the ISO9001 international quality management system certification. GB/T19001-2008 quality management system requirements, GB/T24001-2004 environmental management system requirements, GB/T28001-2011 occupational health and safety management system requirements.
-
Pre-sale commitmentWarmly welcome calls and visits
Provide fast and professional response
Timely, serious and reasonable quotation -
Commitment in saleStrictly execute the contract
Professional technical training
Timely and regular return visits -
After-sales servicePunctual delivery with quality and quantity
Take information feedback seriously
Free lifetime technical consultation